Purpose: This tool performs rigorous physical sizing based on liquid-vapor separation principles.
Gas Disengagement Methodology: Uses the Souders-Brown equation (v_max = K * sqrt((rho_L - rho_G) / rho_G)) to determine the maximum allowable vapor velocity. The K-factor is dependent on the selected demister.
Geometry & Orientation: The sizing algorithm actively links necessary vapor flow area and required liquid volume against the geometric constraints (Horizontal or Vertical cylinder). It enforces the provided Target L/D as a minimum geometric limit to prevent uneconomical, squat vessel dimensions.
Liquid Inventory: Determines surge capacity using target retention times (e.g. typically 3 minutes for phase separators, 1 minute for KO drums and scrubbers).
Nozzle Screening: Preliminary estimates sizing based on generic ρv² and velocity constraints.